Sunny Central 400HE-11 / 500HE-11 / 630HE-11

Search green products
Search green companies
Sunny Central 400HE-11 / 500HE-11 / 630HE-11
Central Inverters
SUNNY CENTRAL- High Tech for solar power stations
We have developed the Sunny Centrals specially for use in large PV power stations and open-field plants. Hence they possess completely special properties. String monitoring, capacity for teamwork and the ability to feed into the medium-voltage power grid make them first choice for PV systems with homogenous structure.
Sunny Central 400HE-11 / 500HE-11 / 630HE-11
Proven high performance
Combining high flexibility with minimum costs and even more power, the distinguished High Efficiency series features a direct connection to a medium-voltage transformer and ensures advantages that pay off thanks to its intelligent power management. This means that the maximum power achieved in continuous operation has been increased by 10 percent, compared to the nominal power at ambient temperatures under 25 °C. The inverters also feature comprehensive grid management functions - including immediate reconnection after a grid voltage drop.
High yields
- Excellent specific price
- Full nominal power up to 50 °C
- 10 % additional power in continuous operation at ambient temperatures up to 25 °C
- Efficiency of more than 98 percent
Flexible
- Integrated DC main distribution for direct connection of string monitors
- Input voltage up to 1000 V supports flexible plant design
- Connection of up to two external DC main distributors for diverse system configuration
Reliable
- Comprehensive grid management functions
- Perfect monitoring of all PV strings in the field
|
Sunny Central 400HE-11 |
Sunny Central 500HE-11 |
Sunny Central 630HE-11 |
|
| Input (DC) | |||
| Max. DC power (@ cos φ=1) | 448 kW | 560 kW | 713 kW |
| Max. input voltage | 1000 V | 1000 V | 1000 V |
| MPP voltage range (@ 25 °C / @ 50 °C at 50 Hz) 1) | 450 V – 820 V / 450 V – 820 V | 450 V – 820 V / 450 V – 820 V | 500 V – 820 V / 500 V – 820 V |
| MPP voltage range (@ 25 °C at 60 Hz) 1) | 450 V – 820 V | 450 V – 820 V | 510 V – 820 V |
| Rated input voltage | 500 V | 500 V | 550 V |
| Minimum input voltage | 450 V | 450 V | 500 V |
| Max. input current | 993 A | 1242 A | 1422 A |
| Number of independent MPP inputs | 1 | 1 | 1 |
| Number of DC inputs | (8+8) + 2 DCHV | (8+8) + 2 DCHV | (8+8) + 2 DCHV |
| Output (AC) | |||
| Rated power (@ 25 °C) / nominal AC power (@ 50 °C) | 440 kVA / 400 kVA | 550 kVA / 500 kVA | 700 kVA / 630 kVA |
| Nominal AC voltage / range | 270 V / 243 V – 297 V | 270 V / 243 V – 297 V | 315 V / 284 V – 346 V |
| AC power frequency / range | 50 Hz, 60 Hz / 47 Hz ... 63 Hz | 50 Hz, 60 Hz / 47 Hz ... 63 Hz | 50 Hz, 60 Hz / 47 Hz ... 63 Hz |
| Rated power frequency / rated power voltage | 50 Hz / 270 V | 50 Hz / 270 V | 50 Hz / 315 V |
| Max. output current | 941 A | 1176 A | 1283 A |
| Max. THD | < 3 % | < 3 % | < 3 % |
| Power factor at rated power / adjustable shift factor | 1 / 0.9 overexcited ... 0.9 underexcited | 1 / 0.9 overexcited ... 0.9 underexcited | 1 / 0.9 overexcited ... 0.9 underexcited |
| Feed-in phases, connection phases | 3 / 3 | 3 / 3 | 3 / 3 |
| Efficiency 2) | |||
| Max. efficiency / European efficiency | 98.6 % / 98.4 % | 98.6 % / 98.4 % | 98.6 % / 98.4 % |
| Protection | |||
| Input side disconnection device | Motor-driven DC switch-disconnector | Motor-driven DC switch-disconnector | Motor-driven DC switch-disconnector |
| Output side disconnection device | AC fuse-switch-disconnector | AC fuse-switch-disconnector | AC fuse-switch-disconnector |
| DC overvoltage protection, AC overvoltage protection | Surge arrester type II / surge arrester type I | Surge arrester type II / surge arrester type I | Surge arrester type II / surge arrester type I |
| Grid monitoring | yes | yes | yes |
| Ground fault monitoring / Remote ground fault monitoring | yes / opt. | yes / opt. | yes / opt. |
| Insulation monitoring | yes | yes | yes |
| Protection (as per IEC 62103) | I | I | I |
| General Data | |||
| Dimensions (W / H / D) |
2800 / 2120 / 850 mm (110.3 / 83.5 / 33.5 inch) |
2800 / 2120 / 850 mm (110.3 / 83.5 / 33.5 inch) |
2800 / 2120 / 850 mm (110.3 / 83.5 / 33.5 inch) |
| Weight | 1900 kg / 4189 lb | 1900 kg / 4189 lb | 1900 kg / 4189 lb |
| Operating temperature range | -20 °C ... +50 °C / -4 °F ... +122 °F | -20 °C ... +50 °C / -4 °F ... +122 °F | -20 °C ... +50 °C / -4 °F ... +122 °F |
| Noise emission 3) | 56.27 db(A) | 56.27 db(A) | 64.2 db(A) |
| Max. self-consumption (in operation) / self-consumption (at night) | 1500 W 4) / < 100 W | 1500 W 4) / < 100 W | 1500 W 4) / < 100 W |
| External auxiliary supply voltage | 3 x 230 V, 50 / 60 Hz | 3 x 230 V, 50 / 60 Hz | 3 x 230 V, 50 / 60 Hz |
| Cooling concept | Forced cooling | Forced cooling | Forced cooling |
| Degree of protection: electronics / connection area (as per IEC 60529) | IP20 / IP20 | IP20 / IP20 | IP20 / IP20 |
| Application | Not air-conditioned indoors | Not air-conditioned indoors | Not air-conditioned indoors |
| Maximum permissible value for relative humidity (non-condensing) | 15 % ... 95 % | 15 % ... 95 % | 15 % ... 95 % |
| Maximum operating altitude above MSL | 1000 m | 1000 m | 1000 m |
| Fresh air consumption | 6200 m³/h | 6200 m³/h | 6200 m³/h |
| Features | |||
| DC terminal | Ring terminal lug / cage terminal | Ring terminal lug / cage terminal | Ring terminal lug / cage terminal |
| AC terminal | Ring terminal lug | Ring terminal lug | Ring terminal lug |
| Display | LC text display | LC text display | LC text display |
| Communication protocols / Sunny String-Monitor | Ethernet, modbus / RS485 | Ethernet, modbus / RS485 | Ethernet, modbus / RS485 |
| Analog inputs / overvoltage protection for analog inputs | 2 x Ain 5) / opt. | 2 x Ain 5) / opt. | 2 x Ain 5) / opt. |
| Internal power supply transformer | opt. | opt. | opt. |
| PV plant monitoring | Optional (via Sunny Portal) | Optional (via Sunny Portal) | Optional (via Sunny Portal) |
| Certifi cates and approvals (more upon request) | EN 61000-6-2, EN 61000-6-4, EMC conformity, CE conformity, BDEW-MSRL / FGW / TR8 6), Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007, Golden Sun CGC / GF 001:2009 | EN 61000-6-2, EN 61000-6-4, EMC conformity, CE conformity, BDEW-MSRL / FGW / TR8 6), Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007, Golden Sun CGC / GF 001:2009 | EN 61000-6-2, EN 61000-6-4, EMC conformity, CE conformity, BDEW-MSRL / FGW / TR8 6), Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007, Golden Sun CGC / GF 001:2009 |
| Type designation | SC 400HE-11 | SC 500HE-11 | SC 630HE-11 |
| HE: High Efficiency, inverter without galvanic isolation for connection to a medium-voltage transformer (taking into account the SMA specification for the transformer) | |||
|
1) At 1.05 VAC, nom and cos φ = 1 2) Efficiency measured without internal power supply at VDC = 500 V 3) Sound pressure level at a distance of 10 m 4) Maximum power in a phase < 1400 W (asymmetrical consumption) 5) 1x irradiation sensor and 1x pyranometer 6) Applies to BDEW-MSRL/FGW/TR6: with limited dynamic grid support |
|||
| Additional features: heating, emergency stop switch |
Additional Information
- manufacturer: SMA Solar Technology / Germany /