SUNNY CENTRAL- High Tech for solar power stations
We have developed the Sunny Centrals specially for use in large PV power stations and open-field plants. Hence they possess completely special properties. String monitoring, capacity for teamwork and the ability to feed into the medium-voltage power grid make them first choice for PV systems with homogenous structure.
Sunny Central 500CP / 630CP / 720CP / 760CP / 800CP
Ensuring highest energy yields
The Sunny Central CP series and Optiprotect not only save you a great amount of money, but also time and effort: Optiprotect integrates the self-learning string failure detection in the inverter and centrally monitors up to 1600 module strings without requiring conventional communication wiring in the field. The self-learning monitoring system simplifies commissioning significantly. 32 motor-driven, adjustable DC inputs ensure maximum plant availability. And thanks to its compact and weatherproof enclosure, the inverters can be loaded and transported with ease and set up almost anywhere.
|
Economical
|
Flexible
|
Efficient
|
Reliable
|
|
Sunny Central 500CP |
Sunny Central 630CP |
Sunny Central 720CP |
Sunny Central 760CP |
Sunny Central 800CP |
|
| Input (DC) | |||||
| Max. DC power (@ cos φ=1) | 560 kW | 713 kW | 808 kW | 853 kW | 898 kW |
| Max. input voltage 1) | 1000 V / 1100 V optional | 1000 V / 1100 V optional | 1000 V / 1100 V optional | 1000 V / 1100 V optional | 1000 V / 1100 V optional |
| MPP voltage range (@ 25 °C / @ 50° C at 50 Hz) | 449 V – 820 V / 430 V – 820 V 2) | 529 V – 820 V / 500 V – 820 V 2) | 577 V – 820 V / 525 V – 820 V 2) 3) | 609 V – 820 V / 554 V – 820 V 2) 3) | 641 V – 820 V / 583 V – 820 V 2) 3) |
| MPP voltage range (@ 25° C / @ 50° C at 60 Hz) | 449 V – 820 V / 436 V – 820 V 2) | 529 V – 820 V / 505 V – 820 V 2) | 577 V – 820 V / 525 V – 820 V 2) 3) | 609 V – 820 V / 554 V – 820 V 2) 3) | 641 V – 820 V / 583 V – 820 V 2) 3) |
| Rated input voltage | 480 V | 550 V | 565 V | 595 V | 620 V |
| Max. input current | 1250 A | 1350 A | 1400 A | 1400 A | 1400 A |
| Minimum input voltage / VMPP_min at IMPP < IDCmax | 429 V / 430 V | 498 V / 500 V | 515 V / 515 V | 545 V / 545 V | 568 V / 570 V |
| Number of independent MPP inputs | 1 | 1 | 1 | 1 | 1 |
| Number of DC inputs | 9 / 32 (Optiprotect) | 9 / 32 (Optiprotect) | 9 / 32 (Optiprotect) | 9 / 32 (Optiprotect) | 9 / 32 (Optiprotect) |
| Output (AC) | |||||
| Rated power (@ 25 °C) / nominal AC power (@ 50 °C) | 550 kVA / 500 kVA | 700 kVA / 630 kVA | 792 kVA / 720 kVA | 836 kVA / 760 kVA | 880 kVA / 800 kVA |
| Nominal AC voltage / range | 270 V / 243 V – 297 V | 315 V / 284 V – 347 V | 324 V / 292 V – 356 V | 342 V / 308 V – 376 V | 360 V / 324 V – 396 V |
| AC power frequency / range | 50 Hz, 60 Hz / 47 Hz ... 63 Hz | 50 Hz, 60 Hz / 47 Hz ... 63 Hz | 50 Hz, 60 Hz / 47 Hz ... 63 Hz | 50 Hz, 60 Hz / 47 Hz ... 63 Hz | 50 Hz, 60 Hz / 47 Hz ... 63 Hz |
| Rated power frequency / rated power voltage | 50 Hz / 270 V | 50 Hz / 315 V | 50 Hz / 324 V | 50 Hz / 342 V | 50 Hz / 360 V |
| Max. output current | 1176 A | 1283 A | 1411 A | 1411 A | 1411 A |
| Max. THD | < 3 % | < 3 % | < 3 % | < 3 % | < 3 % |
| Power factor at rated power / adjustable shift factor | 1 / 0.9 overexcited ... 0.9 underexcited | 1 / 0.9 overexcited ... 0.9 underexcited | 1 / 0.9 overexcited ... 0.9 underexcited | 1 / 0.9 overexcited ... 0.9 underexcited | 1 / 0.9 overexcited ... 0.9 underexcited |
| Feed-in phases / connection phases | 3 / 3 | 3 / 3 | 3 / 3 | 3 / 3 | 3 / 3 |
| Efficiency 7) | |||||
| Max. efficiency / European efficiency / CEC efficiency | 98.6 % / 98.4 % / 98.5 % | 98.7 % / 98.5 % / 98.5 % | 98.6 % / 98.4 % / 98.5 % | 98.6 % / 98.4 % / 98.5 % | 98.6 % / 98.4 % / 98.5 % |
| Protection | |||||
| Input side disconnection device | Motor-driven switch-disconnector / circuit breaker (Optiprotect) | Motor-driven switch-disconnector / circuit breaker (Optiprotect) | Motor-driven switch-disconnector / circuit breaker (Optiprotect) | Motor-driven switch-disconnector / circuit breaker (Optiprotect) | Motor-driven switch-disconnector / circuit breaker (Optiprotect) |
| Output side disconnection device | AC circuit breaker | AC circuit breaker | AC circuit breaker | AC circuit breaker | AC circuit breaker |
| DC overvoltage protection / AC overvoltage protection | Surge arrester type I / surge arrester type I | Surge arrester type I / surge arrester type I | Surge arrester type I / surge arrester type I | Surge arrester type I / surge arrester type I | Surge arrester type I / surge arrester type I |
| Grid monitoring | yes | yes | yes | yes | yes |
| Ground fault monitoring / Remote ground fault monitoring | opt. / opt. | opt. / opt. | opt. / opt. | opt. / opt. | opt. / opt. |
| Insulation monitoring | opt. | opt. | opt. | opt. | opt. |
| Surge arrester for auxiliary supply | yes | yes | yes | yes | yes |
| Protection class (as per IEC 62103) / overvoltage category (as per IEC 60664-1) | I / III | I / III | I / III | I / III | I / III |
| General Data | |||||
| Dimensions (W / H / D) |
2562 / 2279 / 956 mm (101 / 90 / 38 inch) |
2562 / 2279 / 956 mm (101 / 90 / 38 inch) |
2562 / 2279 / 956 mm (101 / 90 / 38 inch) |
2562 / 2279 / 956 mm (101 / 90 / 38 inch) |
2562 / 2279 / 956 mm (101 / 90 / 38 inch) |
| Weight | 1800 kg | 1800 kg | 1800 kg | 1800 kg | 1800 kg |
| Operating temperature range | -20 °C ... +50 °C | -20 °C ... +50 °C | -20 °C ... +50 °C | -20 °C ... +50 °C | -20 °C ... +50 °C |
| Noise emission 5) | 60 db(A) | 60 db(A) | 60 db(A) | 60 db(A) | 61 db(A) |
| Max. self-consumption (in operation) / self-consumption (at night) | 1700 W 4) / < 100 W | 1700 W 4) / < 100 W | 1700 W 4) / < 100 W | 1700 W 4) / < 100 W | 1700 W 4) / < 100 W |
| External auxiliary supply voltage | 230 / 400 V (3 / N / PE) | 230 / 400 V (3 / N / PE) | 230 / 400 V (3 / N / PE) | 230 / 400 V (3 / N / PE) | 230 / 400 V (3 / N / PE) |
| Cooling concept | OptiCool | OptiCool | OptiCool | OptiCool | OptiCool |
| Degree of protection: electronics / connection area (as per IEC 60529) | IP54 / IP23 | IP54 / IP23 | IP54 / IP23 | IP54 / IP23 | IP54 / IP23 |
| Application | Unprotected outdoors | Unprotected outdoors | Unprotected outdoors | Unprotected outdoors | Unprotected outdoors |
| Maximum permissible value for relative humidity (non-condensing) | 15 % ... 95 % | 15 % ... 95 % | 15 % ... 95 % | 15 % ... 95 % | 15 % ... 95 % |
| Maximum operating altitude above MSL | 2000 m | 2000 m | 2000 m | 2000 m | 2000 m |
| Fresh air consumption | 3000 m³/h | 3000 m³/h | 3000 m³/h | 3000 m³/h | 3000 m³/h |
| Features | |||||
| DC terminal | Ring terminal lug / cage terminal (Optiprotect) | Ring terminal lug / cage terminal (Optiprotect) | Ring terminal lug / cage terminal (Optiprotect) | Ring terminal lug / cage terminal (Optiprotect) | Ring terminal lug / cage terminal (Optiprotect) |
| AC terminal | Ring terminal lug | Ring terminal lug | Ring terminal lug | Ring terminal lug | Ring terminal lug |
| Display | opt. | opt. | opt. | opt. | opt. |
| Communication protocols | Ethernet (optical fiber optional), modbus | Ethernet (optical fiber optional), modbus | Ethernet (optical fiber optional), modbus | Ethernet (optical fiber optional), modbus | Ethernet (optical fiber optional), modbus |
| Sunny String-Monitor | RS485 / is not required (Optiprotect) | RS485 / is not required (Optiprotect) | RS485 / is not required (Optiprotect) | RS485 / is not required (Optiprotect) | RS485 / is not required (Optiprotect) |
| Color of enclosure, door, base, roof | RAL 9016 / 9016 / 7005 / 7004 | RAL 9016 / 9016 / 7005 / 7004 | RAL 9016 / 9016 / 7005 / 7004 | RAL 9016 / 9016 / 7005 / 7004 | RAL 9016 / 9016 / 7005 / 7004 |
| Certifi cates and approvals (more upon request) | EN 61000-6-2, EN 61000-6-4, EMV conformity, CE conformity, Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007, BDEW-MSRL / FGW / TR8 6) | EN 61000-6-2, EN 61000-6-4, EMV conformity, CE conformity, Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007, BDEW-MSRL / FGW / TR8 6) | EN 61000-6-2, EN 61000-6-4, EMV conformity, CE conformity, Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007, BDEW-MSRL / FGW / TR8 6) | EN 61000-6-2, EN 61000-6-4, EMV conformity, CE conformity, Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007, BDEW-MSRL / FGW / TR8 6) | EN 61000-6-2, EN 61000-6-4, EMV conformity, CE conformity, Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007, BDEW-MSRL / FGW / TR8 6) |
| Type designation | SC 500CP-10 | SC 630CP-10 | SC 720CP-10 | SC 760CP-10 | SC 800CP-10 |
|
1) Startup at DC voltage < 1000 V 2) At 1.05 VAC, nom and cos φ = 1 3) Further AC voltages, DC voltages and power classes can be configured (for more detailed information, see technical information "Innovations_CP" at www.SMA.de) 4) Self-consumption during nominal operation 5) Sound pressure level at a distance of 10 m 6) With complete dynamic grid support 7) Efficiency measured without internal power supply |