Sunny Island-4548-US / 6048-US

Search green products
Search green companies
Sunny Island-4548-US / 6048-US
Off-Grid Solutions
Here you will find comprehensive system solutions for an autonomous power supply. System components used in such applications include, for instance, Sunny Island inverters in the role of grid and battery manager, inverters for PV, small wind turbine and fuel cell systems and the appropriate monitoring products.And even for grid-tie batteries, SMA's Sunny Backup system is a tried and tested, scalable product solution which includes reliable protection against grid failures.
SUNNY ISLAND - The flexible System manager
The Sunny Islands offer you first class possibilities in the installation of self-sufficient energy systems. In conjunction with a battery pack the devices form a self-sufficient AC voltage grid, which meets with the highest of quality standards.
In the Sunny Island System, electricity generators and consumers are integrated in equal measure. PV and wind energy systems, diesel devices, water or CHP (Combined Heat and Power) can be coupled on the AC side just as conventional 230 Volt consumers.
Sunny Island 4548-US / 6048-US
The Efficient Island Manager: Now with 20 Percent More Power
In the development of the new Sunny Island inverters 4548-US and 6048-US, their efficiency was in particular was optimized. Expanding on the proven technology of Sunny Island 5048-US, they can reach the maximum efficiency level of over 96 % as well as a weighted CEC efficiency level of 94.5 %. This saves diesel costs and enables a smaller dimensioning of PV plants. The new devices for the US market can be used with the SMA multicluster technology for systems with a capacity of up to 100 kW.
|
Efficient
|
Flexible
|
Simple
|
Durable
|
|
Sunny Island 4548-US |
Sunny Island 6048-US |
|
| AC output (loads) | ||
| Nominal AC voltage / adjustable | 120 V / 105 V – 132 V | 120 V / 105 V – 132 V |
| Nominal AC frequency / adjustable | 60 Hz / 55 Hz ... 65 Hz | 60 Hz / 55 Hz ... 65 Hz |
| Continuous AC power (at 25 °C / at 40 °C) for 3 h | 5000 W / 4000 W | 6000 W / 5000 W |
| Continuous AC power (at 25 °C) | 4500 W | 5750 W |
| AC power at 25 °C for 30 min / 1 min / 3 s | 5300 W / 8400 W / 11000 W | 7000 W / 8400 W / 11000 W |
| Nominal AC current / max. AC current (peak) | 37.5 A / 180 A for approx. 60 ms | 48 A / 180 A for approx. 60 ms |
| THD output voltage / power factor at rated power | 3 % / -1 ... +1 | 3 % / -1 ... +1 |
| AC input (generator or grid) | ||
| AC input voltage / range | 120 V / 80 V – 150 V | 120 V / 80 V – 150 V |
| AC input frequency / range | 60 Hz / 54 Hz ... 66 Hz | 60 Hz / 54 Hz ... 66 Hz |
| Max. input current / adjustable | 56 A / 0 A ... 56 A | 56 A / 0 A ... 56 A |
| Max. input power | 6.7 kW | 6.7 kW |
| Battery DC input | ||
| Battery voltage / range | 48 V / 41 V – 63 V | 48 V / 41 V – 63 V |
| Max. battery charging current / continuous charging current at 25 °C | 100 A / 85 A | 130 A / 110 A |
| Battery type / battery capacity | Lead, NiCd / 100 Ah ... 10000 Ah | Lead, NiCd / 100 Ah ... 10000 Ah |
| Charge control | IUoU process | IUoU process |
| Efficiency / self-consumption | ||
| Max. efficiency / CEC efficiency | 96 % / 94.5 % | 96 % / 94 % |
| Self-consumption with no load / standby | 25 W / 4 W | 25 W / 4 W |
| Protection | ||
| DC reverse polarity protection / DC fuse | yes / yes | yes / yes |
| AC short circuit / AC overload | yes / yes | yes / yes |
| Overtemperature / battery deep discharge | yes / yes | yes / yes |
| General data | ||
| Dimensions (W / H / D) |
467 / 612 / 235 mm (18.4 / 24.1 / 9.3 inch) |
467 / 612 / 235 mm (18.4 / 24.1 / 9.3 inch) |
| Weight | 63 kg / 139 lb | 63 kg / 139 lb |
| Operating temperature range |
-25 °C ... +60 °C / -13 °F ... +122 °F |
-25 °C ... +60 °C / -13 °F ... +122 °F |
| Degree of protection (according to IEC 60529) | Interior assembly (NEMA 1) | Interior assembly (NEMA 1) |
| Features / function | ||
| Operation & display / multifunctional relay | Internal / 2 | Internal / 2 |
| 3-phase systems / parallel connection | yes / yes | yes / yes |
| Integrated bypass / multicluster operation | — / yes | — / yes |
| State of charge calculation / full charge / equalization charge | yes / yes / yes | yes / yes / yes |
| Integrated soft start / generator support | yes / yes | yes / yes |
| Battery temperature sensor / communication lines | yes / yes | yes / yes |
| Warranty (5 / 10 / 15 / 20 / 25 years) | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. |
| Certificates and approvals | www.SMA-Solar.com | www.SMA-Solar.com |
| Accessories | ||
| Battery cable / battery fuse | opt. / opt. | opt. / opt. |
| Interface (RS485 / multicluster PB) | opt. / opt. | opt. / opt. |
| Extended generator start "GenMan" | opt. | opt. |
| Load-shedding contactors / external battery current measurement | opt. / opt. | opt. / opt. |
| Type designation | SI4548-US-10 | SI6048-US-10 |
Additional Information
- manufacturer: SMA Solar Technology / Germany /