Sunny Mini Central-4600A / 5000A / 6000A

Search green products
Search green companies
Sunny Mini Central-4600A / 5000A / 6000A
Sunny Mini Central
No Other Pays Off Faster
Peak efficiencies of 98 % and a low specific price: The Sunny Mini Centrals promise high yields and short payback times.
The devices are optimally suited to the setup of mid-range PV systems from 15 kW. They are fitted with die-cast aluminum housings and can be installed outdoors close to the generator. Graded power classes ensure maximum planning freedom.
Sunny Mini Central 4600A / 5000A / 6000A
Proven technology for a multitude of applications
The Sunny Mini Central 4600A, 5000A and 6000A are installed wherever galvanic isolation is required. This means they can be universally used for many different types of connections. In this way, the Sunny Mini Centrals can be used with crystalline cells as well as thin-film modules. Thanks to their graduated performance classes, they offer the highest degree of flexibility in plant design. The Sunny Mini Centrals 5000A and 6000A are also ideal for three-phase systems, while the Sunny Mini Central 4600A is designed for single-phase PV plants.
|
Powerful
|
Flexible
|
Reliable
|
Simple
|
|
Sunny Mini Central 4600A |
Sunny Mini Central 5000A |
Sunny Mini Central 6000A |
|
| Input (DC) | |||
| Max. DC power (@ cos φ=1) | 5250 W | 5750 W | 6300 W |
| Max. input voltage | 600 V | 600 V | 600 V |
| MPP voltage range / rated input voltage | 246 V – 480 V / 246 V | 246 V – 480 V / 246 V | 246 V – 480 V / 246 V |
| Min. input voltage / initial input voltage | 211 V / 300 V | 211 V / 300 V | 211 V / 300 V |
| Max. input current | 26 A | 26 A | 26 A |
| Max. input current per string | 26 A | 26 A | 26 A |
| Number of independent MPP inputs / strings per MPP input | 1 / 4 | 1 / 4 | 1 / 4 |
| Output (AC) | |||
| Rated output power (@230 V, 50 Hz) | 4600 W | 5000 W | 6000 W |
| Max. apparent AC power | 5000 VA | 5500 VA | 6000 VA |
| AC nominal voltage / range | 220 V, 230 V, 240 V / 160 V – 265 V | 220 V, 230 V, 240 V / 160 V – 265 V | 220 V, 230 V, 240 V / 160 V – 265 V |
| AC power frequency / range | 50 Hz, 60 Hz / 6 Hz ... 5 Hz | 50 Hz, 60 Hz / -6 Hz ... +5 Hz | 50 Hz, 60 Hz / -6 Hz ... +5 Hz |
| Rated power frequency / rated power voltage | 50 Hz / 230 V | 50 Hz / 230 V | 50 Hz / 230 V |
| Max. output current | 26 A | 26 A | 26 A |
| Power factor at rated output power | 1 | 1 | 1 |
| Adjustable displacement factor | — | — | — |
| Feed-in phases / connection phases | 1 / 1 | 1 / 1 | 1 / 1 |
| Power balancing | yes | yes | yes |
| Efficiency | |||
| Max. efficiency / European efficiency | 96.1 % / 95.3 % | 96.1 % / 95.3 % | 96.1 % / 95.3 % |
| Protection | |||
| Reverse current protection / input-side disconnection device | — / yes | — / yes | — / yes |
| Ground fault monitoring / grid monitoring | yes / yes | yes / yes | yes / yes |
| DC reverse-polarity protection / AC short-circuit current capability / galvanically isolated | yes / yes / yes | yes / yes / yes | yes / yes / yes |
| All-pole sensitive residual current monitoring unit | — | — | — |
| Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | I / III | I / III | I / III |
| General Data | |||
| Dimensions (W / H / D) |
468 / 613 / 242 mm (18.4 / 24.1 / 9.5 inch) |
468 / 613 / 242 mm (18.4 / 24.1 / 9.5 inch) |
468 / 613 / 242 mm (18.4 / 24.1 / 9.5 inch) |
| Weight | 62 kg / 136.69 lb | 62 kg / 136.69 lb | 63 kg / 138.89 lb |
| Operating temperature range |
-25 °C ... +60 °C / -13 °F ... +140 °F |
-25 °C ... +60 °C / -13 °F ... +140 °F |
-25 °C ... +60 °C / -13 °F ... +140 °F |
| Noise emission (typical) | 42 dB(A) | 42 dB(A) | 42 dB(A) |
| Internal consumption (night) | 0.25 W | 0.25 W | 0.25 W |
| Topology | LF transformer | LF transformer | LF transformer |
| Cooling concept | OptiCool | OptiCool | OptiCool |
| Degree of protection (according to IEC 60529) | IP65 | IP65 | IP65 |
| Degree of protection of connection area (according to IEC 60529) | IP65 | IP65 | IP65 |
| Climatic category (according to IEC 60721-3-4) | 4K4H | 4K4H | 4K4H |
| Maximum permissible value for relative humidity (non-condensing) | 100 % | 100 % | 100 % |
| Features | |||
| DC terminal | SUNCLIX | SUNCLIX | SUNCLIX |
| AC terminal | Screw terminal | Screw terminal | Screw terminal |
| Display | Text line | Text line | Text line |
| Interface: RS485 / Bluetooth | opt. / opt. | opt. / opt. | opt. / opt. |
| Warranty: 5 / 10 / 15 / 20 / 25 years | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. |
| Certificates and approvals (more available on request) | CE, VDE0126-1-1, DK 5940 ED2.2**, G83/1-1, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, PPDS, UTE C15-712-1, C10/11, IEC 61727 | CE, VDE0126-1-1, DK 5940 ED2.2**, G83/1-1, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, PPDS, UTE C15-712-1, C10/11, IEC 61727 | CE, VDE0126-1-1, DK 5940 ED2.2**, G83/1-1, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, UTE C15-712-1, C10/11, PPDS, IEC 61727 |
|
* Does not apply to all national deviations of EN 50438 ** Only applies to IT option |
|||
| Data at nominal conditions | |||
| Type designation | SMC 4600A | SMC 5000A | SMC 6000A |
Additional Information
- manufacturer: SMA Solar Technology / Germany /