Sunny Tripower-8000TL / 10000TL / 12000TL / 15000TL / 17000TL

Search green products
Search green companies
Sunny Tripower-8000TL / 10000TL / 12000TL / 15000TL / 17000TL
The three-phase inverter for easy plant design
Full of pioneering technology: highly flexible plant design with the three-phase Sunny Tripower inverter. Thanks to Optiflex technology, two MPP inputs and a broad input voltage range, it is suited to almost any module configuration. It meets any requirement such as reactive power supply, grid support thus reliably participating in grid management. The safety concept Optiprotect with self-learning string-failure detection, electronic string fuse and integrable DC surge arrester, type II ensures maximum availability.
|
Efficient
|
Flexible
|
Safe
|
Simple
|
|
Sunny Tripower 8000TL |
Sunny Tripower 10000TL |
Sunny Tripower 12000TL |
Sunny Tripower 15000TL |
Sunny Tripower 17000TL |
|
| Input (DC) | |||||
| Max. DC power (@ cos φ=1) | 8200 W | 10200 W | 12250 W | 15340 W | 17410 W |
| Max. input voltage | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V |
| MPP voltage range / rated input voltage | 320 V – 800 V / 600 V | 320 V – 800 V / 600 V | 380 V – 800 V / 600 V | 360 V – 800 V / 600 V | 400 V – 800 V / 600 V |
| Min. input voltage / initial input voltage | 150 V / 188 V | 150 V / 188 V | 150 V / 188 V | 150 V / 188 V | 150 V / 188 V |
| Max. input current input A / input B | 22 A / 11 A | 22 A / 11 A | 22 A / 11 A | 33 A / 11 A | 33 A / 11 A |
| Max. input current per string input A** / input B** | 33 A / 12.5 A | 33 A / 12.5 A | 33 A / 12.5 A | 33 A / 12.5 A | 33 A / 12.5 A |
| Number of independent MPP inputs / strings per MPP input | 2 / A:4; B:1 | 2 / A:4; B:1 | 2 / A:4; B:1 | 2 / A:5; B:1 | 2 / A:5; B:1 |
| Output (AC) | |||||
| Rated power (@ 230 V, 50 Hz) | 8000 W | 10000 W | 12000 W | 15000 W | 17000 W |
| Max. apparent AC power | 8000 VA | 10000 VA | 12000 VA | 15000 VA | 17000 VA |
| Nominal AC voltage | 3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V | 3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V | 3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V | 3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V | 3 / N / PE; 220 / 380 V 3 / N / PE; 230 / 400 V 3 / N / PE; 240 / 415 V |
| Nominal AC voltage range | 160 V – 280 V | 160 V – 280 V | 160 V – 280 V | 160 V – 280 V | 160 V – 280 V |
| AC power frequency / range | 50 Hz, 60Hz / -6 Hz ... +5 Hz | 50 Hz, 60Hz / -6 Hz ... +5 Hz | 50 Hz, 60Hz / -6 Hz ... +5 Hz | 50 Hz, 60Hz / -6 Hz ... +5 Hz | 50 Hz, 60Hz / -6 Hz ... +5 Hz |
| Rated grid frequency / rated grid voltage | 50 Hz / 230 V | 50 Hz / 230 V | 50 Hz / 230 V | 50 Hz / 230 V | 50 Hz / 230 V |
| Max. output current | 16 A | 16 A | 19.2 A | 24 A | 24.6 A |
| Power factor at rated power | 1 | 1 | 1 | 1 | 1 |
| Adjustable displacement factor | 0.8 overexited ... 0.8 underexited | 0.8 overexited ... 0.8 underexited | 0.8 overexited ... 0.8 underexited | 0.8 overexited ... 0.8 underexited | 0.8 overexited ... 0.8 underexited |
| Phase conductors / connection phases | 3 / 3 | 3 / 3 | 3 / 3 | 3 / 3 | 3 / 3 |
| Efficiency | |||||
| Max. efficiency / European efficiency | 98.1 % / 97.5 % | 98.1 % / 97.7 % | 98.1 % / 97.7 % | 98.2 % / 97.8 % | 98.2 % / 97.8 % |
| Protection | |||||
| Input-side disconnection device | yes | yes | yes | yes | yes |
| Ground-fault monitoring / grid monitoring | yes / yes | yes / yes | yes / yes | yes / yes | yes / yes |
| DC surge arrester Type II, can be integrated | opt. | opt. | opt. | opt. | opt. |
| DC reverse-polarity protection / AC short-circuit current capability / galvanically isolated | yes / yes / — | yes / yes / — | yes / yes / — | yes / yes / — | yes / yes / — |
| All-pole sensitive residual current monitoring unit | yes | yes | yes | yes | yes |
| Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | I / III | I / III | I / III | I / III | I / III |
| General Data | |||||
| Dimensions (W / H / D) |
665 / 690 / 265 mm (26.2 / 27.2 / 10.4 inch) |
665 / 690 / 265 mm (26.2 / 27.2 / 10.4 inch) |
665 / 690 / 265 mm (26.2 / 27.2 / 10.4 inch) |
665 / 690 / 265 mm (26.2 / 27.2 / 10.4 inch) |
665 / 690 / 265 mm (26.2 / 27.2 / 10.4 inch) |
| Weight | 64 kg / 141.1 lb | 64 kg / 141.1 lb | 64 kg / 141.1 lb | 64 kg / 141.1 lb | 64 kg / 141.1 lb |
| Operating temperature range |
-25 °C ... +60 °C / -13 °F ... +140 °F |
-25 °C ... +60 °C / -13 °F ... +140 °F |
-25 °C ... +60 °C / -13 °F ... +140 °F |
25 °C ... +60 °C / -13 °F ... +140 °F |
-25 °C ... +60 °C / -13 °F ... +140 °F |
| Noise emission (typical) | 51 dB(A) | 51 dB(A) | 51 dB(A) | 51 dB(A) | 51 dB(A) |
| Self-consumption at night | 1 W | 1 W | 1 W | 1 W | 1 W |
| Topology / cooling concept | Transformerless / OptiCool | Transformerless / OptiCool | Transformerless / OptiCool | Transformerless / OptiCool | Transformerless / OptiCool |
| Degree of protection / degree of protection of connection area (according to IEC 60529) | IP65 / IP54 | IP65 / IP54 | IP65 / IP54 | IP65 / IP54 | IP65 / IP54 |
| Climatic category (according to IEC 60721-3-4) | 4K4H | 4K4H | 4K4H | 4K4H | 4K4H |
| Maximum permissible value for relative humidity (non-condensing) | 100 % | 100 % | 100 % | 100 % | 100 % |
| Features | |||||
| DC terminal | SUNCLIX | SUNCLIX | SUNCLIX | SUNCLIX | SUNCLIX |
| AC terminal | Spring-type terminal | Spring-type terminal | Spring-type terminal | Spring-type terminal | Spring-type terminal |
| Display | Graphic | Graphic | Graphic | Graphic | Graphic |
| Interface: RS485 / Bluetooth | opt. / yes | opt. / yes | opt. / yes | opt. / yes | opt. / yes |
| Warranty: 5 / 10 / 15 / 20 / 25 years | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. |
| Multi-function relay | yes | yes | yes | yes | yes |
| Certificates and approvals (more available on request) | CE, VDE0126-1-1, G83/1-1, RD 1663/2000, RD 661/2007, G59/2, PPC, AS4777, EN 50438*, C10/11, PPDS, IEC 61727, ENEL-Guida, UTE C15-712-1 | CE, VDE0126-1-1, G83/1-1, RD 1663/2000, RD 661/2007, G59/2, PPC, AS4777, EN 50438*, C10/11, PPDS, IEC 61727, ENEL-Guida, UTE C15-712-1 | CE, VDE0126-1-1, G83/1-1, RD 1663/2000, RD 661/2007, G59/2, PPC, AS4777, EN 50438*, C10/11, PPDS, IEC 61727, ENEL-Guida, UTE C15-712-1 | CE, VDE0126-1-1, G83/1-1, RD 1663/2000, RD 661/2007, G59/2, PPC, AS4777, EN 50438*, C10/11, PPDS, IEC 61727, ENEL-Guida, UTE C15-712-1 | CE, VDE0126-1-1, G83/1-1, RD 1663/2000, RD 661/2007, G59/2, PPC, AS4777, EN 50438*, C10/11, PPDS, IEC 61727, ENEL-Guida, UTE C15-712-1 |
|
* Does not apply to all national deviations of EN 50438 ** To be observed in case of a short circuit in the electronic string fuse |
|||||
| Data at nominal conditions | |||||
| Type designation | STP 8000TL-10 | STP 10000TL-10 | STP 12000TL-10 | STP 15000TL-10 | STP 17000TL-10 |
Additional Information
- manufacturer: SMA Solar Technology / Germany /