Windy Boy 3000-US

Search green products
Search green companies
Windy Boy 3000-US
Wind energy
WINDY BOY - grid-coupling small wind energy plants
The grid-coupling of small wind energy plants is simpler than ever - with the Windy Boy from SMA. It converts the variable frequency voltage from wind generators into grid conforming AC voltage. Thus the energy can be used privately, excess energy fed into the mains grid and respectively remunerated. The Windy Boy works perfectly together with the Sunny Island in stand-alone grids for the electrification of remote areas.
Windy Boy 3000-US
A reliable option with UL certification
User-friendly, safe and reliable: the Windy Boy 3000-US is specially certified for the US market. The automatic grid voltage detection* allows for a straightforward and secure installation. The aluminum die-cast enclosure and the OptiCool active cooling system ensure optimal yield as well as a long lifespan, even under adverse operating conditions.
* US patent US7352549B1
|
UL Certified
|
Simple
|
Economical
|
Reliable
|
|
Windy Boy 3000-US |
|
|
208 V 240 V |
|
| Input (DC) | |
| Max. DC power (@ cos φ=1) | 3200 W |
| Max. input voltage / nominal DC voltage | 500 V / 250 V |
| Min. open-circuit voltage for activating "Turbine Mode" | 230 V |
| Voltage range in "Turbine Mode" |
175 V – 500 V 200 V – 500 V |
| Max. input current | 17 A |
| Output (AC) | |
| Rated output power (@ 230 V, 50 Hz) | 3000 W |
| Max. apparent AC power | 3000 VA |
| Nominal AC voltage / range |
208 V / 183 V – 229 V 240 V / 211 V – 264 V |
| Power line frequency / range | 60 Hz / 59.3 Hz ... 60.5 Hz |
| Rated power frequency / rated power voltage |
60 Hz / 208 V 60 Hz / 240 V |
| Max. output current | 15 A |
| Power factor at rated output power | 1 |
| Feed-in phases / connection phases | 1 / 1 |
| Efficiency | |
| Max. efficiency / CEC efficiency |
96 % / 95 % 96.5 % / 95.5 % |
| Protection | |
| DC reverse polarity protection / AC short-circuit current capability / galvanically isolated | yes / yes / yes |
| Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | I / III |
| General data | |
| Dimensions (W / H / D) |
450 / 352 / 236 mm (17.7 / 13.9 / 9.3 inch) |
| Weight | 40 kg / 88 lb |
| Operating temperature range |
-25 °C ... +45 °C / -13 °F ... +113 °F |
| Noise emission | 40 db(A) |
| Topology | LF transformer |
| Cooling concept | OptiCool |
| Protection class of electronics / connection area (according to IEC 60529) | NEMA 3R / NEMA 3R |
| Features | |
| Display | Text line |
| Interfaces: RS485 / Bluetooth | opt. / opt. |
| Warranty: 10 years | yes |
| Certificates and approvals (additional on request) | UL1741, UL1998, IEEE1547, FCC Part 15 (Class A & B) |
| Data at nominal conditions | |
| Type designation | WB 3000US |
Additional Information
- manufacturer: SMA Solar Technology / Germany /