SUNNY CENTRAL- High Tech for solar power stations

We have developed the Sunny Centrals specially for use in large PV power stations and open-field plants. Hence they possess completely special properties. String monitoring, capacity for teamwork and the ability to feed into the medium-voltage power grid make them first choice for PV systems with homogenous structure.

The Sunny Centrals are easy to install - indoors as well as outdoors. With peak efficiencies of over 98 % they belong to the most efficient central inverters on the market. maximum reliability and durability furthermore ensures the greatest investment security.


Sunny Central 400MV / 500MV / 630MV

for direct medium-voltage feed-in


The compact station for safe grid management

Equipped with an SMA central inverter of the new HE product line and a medium-voltage transformer, the Sunny Central MV feeds directly into the medium-voltage grid. By removing the need for low-voltage transformers and simultaneously employing the amorphous transformer, efficiency is increased and, at the same time, inverter costs are lowered. The Sunny Central MV is delivered as a turnkey concrete substation for outside installation.


Efficient

  • Greater efficiency without lowvoltage transformers due to direct connection to the medium-voltage grid


Turnkey delivery

  • Complete with medium-voltage transformer and concrete substation for outdoor installation


Optional

  • Medium-voltage switchgear systems for a flexible structure in designing large PV farms
  • AC transfer station with measurement
  • Medium-voltage transformers for other grid voltages (deviating from 20 kV)
  • Amorphous transformer for minimal open circuit losses


  Sunny Central
400MV
Sunny Central
500MV
Sunny Central
630MV
Input (DC)      
Max. DC power (@ cos φ=1) 455 kW 567 kW 723 kW
Max. input voltage 1000 V 1000 V 1000 V
MPP voltage range (@ 25 °C / @ 45 °C at 50 Hz) 1) 450 V - 820 V / 450 V - 820 V 450 V – 820 V 1) 500 V – 820 V / 500 V – 820 V
MPP voltage range (@ 25 °C at 60 Hz) 1) 450 V – 820 V 450 V – 820 V 1) 510 V – 820 V
Rated input voltage 500 V 500 V 550 V
Max. input current 993 A 1242 A 1422 A
Minimum input voltage 450 V 450 V 500 V
Number of independent MPP inputs 1 1 1
Number of DC inputs (8+8) + 2 DCHV (8+8) + 2 DCHV (8+8) + 2 DCHV
       
Output (AC)      
Rated power (@ 25 °C) / nominal AC power (@ 45 °C) 440 kVA / 400 kVA 550 kVA / 500 kVA 700 kVA / 630 kVA
Nominal AC voltage / range 20000 V / 18000 V – 22000 V 20000 V / 18000 V – 22000 V 20000 V / 18000 V – 22000 V
AC power frequency / range 50 Hz, 60 Hz / 47 Hz ... 63 Hz 50 Hz, 60 Hz / 47 Hz ... 63 Hz 50 Hz, 60 Hz / 47 Hz ... 63 Hz
Rated power frequency / rated power frequency 50 Hz / 20000 V 50 Hz / 20000 V 50 Hz / 20000 V
Max. output current 12.7 A 15.9 A 20.2 A
Max. THD < 3 % < 3 % < 3 %
Power factor at rated power / adjustable shift factor 1 / 0.9 overexcited ... 0.9 underexcited 1 / 0.9 overexcited ... 0.9 underexcited 1 / 0.9 overexcited ... 0.9 underexcited
Feed-in phases / connection phases 3 / 3 3 / 3 3 / 3
       
Efficiency 2)      
Max. efficiency / European efficiency 97.5 % / 97.1 % 97.7 % / 97.3 % 97.8 % / 97.4 %
       
Protection      
Input side disconnection device Motor-driven DC switch-disconnector Motor-driven DC switch-disconnector Motor-driven switch-disconnector on DC side
Output side disconnection device AC fuse-switch-disconnector AC fuse-switch-disconnector AC fuse-switch-disconnector
DC overvoltage protection / AC overvoltage protection Surge arrester type II / surge arrester type I Surge arrester type II / surge arrester type I Surge arrester type II / surge arrester type I
Grid monitoring yes yes yes
Ground fault monitoring / Remote ground fault monitoring yes / opt. yes / opt. yes / opt.
Insulation monitoring yes yes yes
Galvanic isolation yes yes yes
Surge arrester for auxiliary supply yes yes yes
Protection class (as per IEC 62103) I I I
       
General Data      
Dimensions (W / H / D) 5300 / 3600 / 2500 mm
(208.7 / 141.7 / 98.4 inch)
5300 / 3600 / 2500 mm
(208.7 / 141.7 / 98.4 inch)
5300 / 3600 / 2500 mm
(208.7 / 141.7 / 98.4 inch)
Weight 30000 kg / 66139 lb 30000 kg / 66139 lb 30000 kg / 66139 lb
Operating temperature range -20 °C ... +45 °C / -4 °F ... +113 °F 20 °C ... +45 °C / -4 °F ... +113 °F -20 °C ... +45 °C / -4 °F ... +113 °F
Max. self-consumption (in operation) / self-consumption (at night) 1500 W 3) / < 100 W + 720 W 5) 1500 W 3) / < 100 W + 720 W 5) 1500 W 3) / < 100 W + 860 W 5)
External auxiliary supply voltage / External back-up fuse for auxiliary supply 3 x 230 V, 50 / 60 Hz / B 20 A, 3 Pole 3 x 230 V, 50 / 60 Hz / B 20 A, 3 Pole 3 x 230 V, 50 / 60 Hz / B 20 A, 3-pole
Cooling concept Forced cooling Forced cooling Forced cooling
Degree of protection: electronics / connection area (as per IEC 60529) IP20 / IP54 IP20 / IP54 IP20 / IP54
Application Unprotected outdoors Unprotected outdoors Unprotected outdoors
Maximum permissible value for relative humidity (non-condensing) 15 % ... 95 % 15 % ... 95 % 15 % ... 95 %
Maximum operating altitude above MSL 1000 m 1000 m 1000 m
Fresh air consumption 6200 m³/h 6200 m³/h 6200 m³/h
       
Features      
DC terminal Ring terminal lug / cage terminal Ring terminal lug / cage terminal Ring terminal lug / cage terminal
AC terminal Ring terminal lug Ring terminal lug Ring terminal lug
Display LC text display LC text display LC text display
Communication interfaces / Sunny String-Monitor Ethernet, modbus / RS485 Ethernet, modbus / RS485 Ethernet, modbus / RS485
Analog inputs / overvoltage protection for analog inputs 2 x Ain 4) / opt. 2 x Ain 4) / opt. 2 x Ain 4) / opt.
Internal power supply transformer opt. opt. opt.
Medium-voltage transformer with amorphous core opt. opt. opt.
Medium-voltage switchgear opt. opt. opt.
Color of enclosure / door / base / roof RAL 7035 / 7024 / 7024 / 7024 RAL 7035 / 7024 / 7024 / 7024 RAL 7035 / 7024 / 7024 / 7024
Certificates and approvals (more upon request) EN 61000-6-2, EN 61000-6-4, EMC conformity, CE conformity, BDEW-MSRL / FGW / TR8 6), Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007 EN 61000-6-2, EN 61000-6-4, EMC conformity, CE conformity, BDEW-MSRL / FGW / TR8 6), Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007 EN 61000-6-2, EN 61000-6-4, EMC conformity, CE conformity, BDEW-MSRL / FGW / TR8 6), Arrêté du 4/23/08, R.D. 1663 / 2000, R.D. 661 / 2007
       
Type designation SC 400MV-11 SC 500MV-11 SC 630MV-11
       
HE: High Efficiency, inverter without galvanic isolation for connection to a medium-voltage transformer (taking into account the SMA specification for the transformer)      
1) At 1.05 VAC, nom and cos φ = 1
2) Efficiency measured without an internal power supply at VDC = 500 V
3) Maximum power in a phase for each inverter < 1400 W (asymmetrical consumption)
4) Each with 1x irradiation sensor and 1x pyranometer
5) Disconnected according to the transformer’s open circuit losses and inverter consumption
6) Applies to BDEW-MSRL/FGW/TR8: with limited dynamic grid support
     
Please note: In certain countries the substations may differ from the concept shown in the images.    

Additional Information

  • manufacturer:  SMA Solar Technology / Germany /
Total Views: 2652

More products from this category

Wind turbines-300W

A renewable form of energy and a kinetic energy of air masses in the atmosphere .....

Wind turbines-500W

A renewable form of energy and a kinetic energy of air masses in the atmosphere .....

Wind turbines-1000W

A renewable form of energy and a kinetic energy of air masses in the atmosphere .....

Wind turbines-2000W

A renewable form of energy and a kinetic energy of air masses in the atmosphere .....